Midea/midea_ac_lan/midea/devices/b3/device.py
2023-09-22 07:45:40 +02:00

122 lines
4.8 KiB
Python

import logging
from .message import (
MessageQuery,
MessageB3Response
)
try:
from enum import StrEnum
except ImportError:
from ...backports.enum import StrEnum
from ...core.device import MiedaDevice
_LOGGER = logging.getLogger(__name__)
class DeviceAttributes(StrEnum):
top_compartment_status = "top_compartment_status"
top_compartment_mode = "top_compartment_mode"
top_compartment_temperature = "top_compartment_temperature"
top_compartment_remaining = "top_compartment_remaining"
top_compartment_door = "top_compartment_door"
top_compartment_preheating = "top_compartment_preheating"
top_compartment_cooling = "top_compartment_cooling"
middle_compartment_status = "middle_compartment_status"
middle_compartment_mode = "middle_compartment_mode"
middle_compartment_temperature = "middle_compartment_temperature"
middle_compartment_remaining = "middle_compartment_remaining"
middle_compartment_door = "middle_compartment_door"
middle_compartment_preheating = "middle_compartment_preheating"
middle_compartment_cooling = "middle_compartment_cooling"
bottom_compartment_status = "bottom_compartment_status"
bottom_compartment_mode = "bottom_compartment_mode"
bottom_compartment_temperature = "bottom_compartment_temperature"
bottom_compartment_remaining = "bottom_compartment_remaining"
bottom_compartment_door = "bottom_compartment_door"
bottom_compartment_preheating = "bottom_compartment_preheating"
bottom_compartment_cooling = "bottom_compartment_cooling"
lock = "lock"
class MideaB2Device(MiedaDevice):
_status = {
0x00: "Off", 0x01: "Standby", 0x02: "Working",
0x03: "Delay", 0x04: "Finished"
}
def __init__(
self,
name: str,
device_id: int,
ip_address: str,
port: int,
token: str,
key: str,
protocol: int,
model: str,
customize: str
):
super().__init__(
name=name,
device_id=device_id,
device_type=0xB1,
ip_address=ip_address,
port=port,
token=token,
key=key,
protocol=protocol,
model=model,
attributes={
DeviceAttributes.top_compartment_status: None,
DeviceAttributes.top_compartment_mode: None,
DeviceAttributes.top_compartment_temperature: None,
DeviceAttributes.top_compartment_remaining: None,
DeviceAttributes.top_compartment_door: False,
DeviceAttributes.top_compartment_preheating: False,
DeviceAttributes.top_compartment_cooling: False,
DeviceAttributes.middle_compartment_status: None,
DeviceAttributes.middle_compartment_mode: None,
DeviceAttributes.middle_compartment_temperature: None,
DeviceAttributes.middle_compartment_remaining: None,
DeviceAttributes.middle_compartment_door: False,
DeviceAttributes.middle_compartment_preheating: False,
DeviceAttributes.middle_compartment_cooling: False,
DeviceAttributes.bottom_compartment_status: None,
DeviceAttributes.bottom_compartment_mode: None,
DeviceAttributes.bottom_compartment_temperature: None,
DeviceAttributes.bottom_compartment_remaining: None,
DeviceAttributes.bottom_compartment_door: False,
DeviceAttributes.bottom_compartment_preheating: False,
DeviceAttributes.bottom_compartment_cooling: False,
DeviceAttributes.lock: False,
})
def build_query(self):
return [MessageQuery(self._device_protocol_version)]
def process_message(self, msg):
message = MessageB3Response(msg)
_LOGGER.debug(f"[{self.device_id}] Received: {message}")
new_status = {}
for status in self._attributes.keys():
if hasattr(message, str(status)):
value = getattr(message, str(status))
if status in [
DeviceAttributes.top_compartment_status,
DeviceAttributes.middle_compartment_status,
DeviceAttributes.bottom_compartment_status
]:
if value in MideaB2Device._status.keys():
self._attributes[status] = MideaB2Device._status.get(value)
else:
self._attributes[status] = None
else:
self._attributes[status] = value
new_status[str(status)] = self._attributes[status]
return new_status
def set_attribute(self, attr, value):
pass
class MideaAppliance(MideaB2Device):
pass